BCGPS - DIAZINON AG500
- MSDS: BCGPS
- Manufacturer: CIBA GEIGY CORP AGRICULTURAL DIV
- Product Name: DIAZINON AG500
- National Stock Number: 6840-00N000912
Product Identification
Product ID:DIAZINON AG500
MSDS Date:01/01/1985
FSC:6840
NIIN:00N000912
MSDS Number: BCGPS
Responsible Party
GREENSBORO, NC 27419
Emergency Phone: 800-888-8372 OR 800-334-9481
Info Phone: 919-292-7100
Cage: 8K340
Contractor
Telephone: 800-888-8372 OR 800-334-9481
Cage: 8K340
Ingredients
DIAZINON (SARA III)
CAS: 333-41-5
RTECS: TF3325000
Fraction By Weight: 48%
OSHA PEL S, 0.1 MG/M3
ACGIH TLV: S, 0.1 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
AROMATIC PETROLEUM DERIVATIVE SOLVENT
Fraction By Weight: 36%
ACGIH TLV: S, 100PPM (MFR)
Hazards
Effects of Overexposure:MILDLY IRRIT TO SKIN, MOD IRRIT TO EYE
(RABBIT). HDCH,WEAK,NAUSEA, RESP DIFF,CONVUL ETC.(SEE SUP DAT
First Aid
First Aid:EYES:FLUSH W/LG QTY OF WATER 15 MIN & GET MEDICAL ATTN.
SKIN:WASH W/ SOAP & WATER. INH: MOVE TO CLEAR ATMOSPHERE. IF
SYMPTOMS OCCUR, GET MEDICAL ATTN. INGEST: IF CONSCIOUS, GIVE WATER
OR MILK. DO NOT INDUCE VOMITING (SEE SUP DATA).
Fire Fighting
Flash Point:108F TCC MINIMUM
Extinguishing Media:DRY CHEMICAL, CO*2
Fire Fighting Procedures:TREAT AS OIL/GASOLINE TYFIRE, CONFINE & REDUCE
VAPOR QUICKLY
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID.
Accidental Release
Spill Release Procedures:SOAK UP W/ABSORBENT MATERIAL (I.E., LIME) &
SWEEP INTO A DISPOSABLE BAG. WASH SURVACE W/WARM WATER &
DETERGENT.THEN W/CAUSTIC SOLUTION. DO NOT ALLOW WATER TO CONTAM
WATER SUPPLIES. NEUTRALIZING CHEM: CAUSTIC ACID OR BASE. (MFR
RECM).
Handling
Handling and Storage Precautions:KEEP AWAY FROM IGNIT SOURCES. KEEP
CONTAINER CLSD. USE W/ADEQ VENTIL. DO NOT REUSE EMPTY CONTAINER.
MFR RECM DESTROY & BURY IN A SAFE PLACE.
Other Precautions:POSS FATAL IF INGEST. MAY BE ABOSRBED BY SKIN. DO NOT
BRTH SPRAY MIST. KEEP FRM SKIN, EYES & CLOTHES. WASH AFTER
HANDLING. KEEP FROM WATER SOURCES,CHILDREN,FOOD,FEED & ANIMALS.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPRVD RESP DEVICE IN UNUSUAL CASES.
(SEE SUPP DATA).
Ventilation:WELL VENTILATED AREA. DO NOT BREATHE FUMES.
Protective Gloves:RUBBER
Eye Protection:GOGGLES IN UNUSUAL CASES
Other Protective Equipment:CLOTHING & EQUIP CONSISTANT W/GOOD PESTICIDE
HANDLING/USE.
Supplemental Safety and Health
MFR RECM MSA CONFO II PESTICIDE RESP IF NEC. NOTE TO MD; ATROPINE IS
ANTIDOTE IF USED EARLY & DOSE OF DIAZINON NOT TOO GREAT
RESP,ANTIDOTE,2-PAM IV,LAVG
Chemical Properties
HCC:F5
Boiling Pt:B.P. Text:190C DECOMP
Vapor Pres:2
Spec Gravity:0.997
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LT TO MED BROWN LIQ W/SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTAM W/WATER, ACIDS OR ALKALINES.
Stability Condition to Avoid:STORAGE AT HIGH TEMP, MOISTURE.NO DECOMP
PROD W/ EXCESS H*2O
Hazardous Decomposition Products:MONOTHIONO TEPP & DIAZOXON IF EXPOS TO
SM AMTS OF WATER
Disposal
Waste Disposal Methods:MFR RECM COVER W/DIRT, CLAY OR SAND. DO NOT
CONTAMINATE WATER SUPPLIES. DISPOSE IAW FED, STATE & LOCAL CODES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.